Resona 7 - ZST+

V Flow

A novel visualization of blood flow, in which in which color arrows are displayed, instead of the color map of a conventional Doppler ultrasound image.

slidebg1
Conventional method

New method

Benefits

Extremely high frame-rate flow imaging over 600 frames per second

Both the velocity and direction of the blood flow can be clearly displayed

Laminar, vortex, secondary, and retrograde flows can be illustrated in complex flow imaging

Intuitive display dynamically shows the flow process with color arrows

Quantitative measurement of velocity and direction at an arbitrary location




CFM

  V Flow



Applications above

Jugular vein and carotid bifurcation where the CCA, ICA and ECA are shown in one image. Detailed hemodynamic is lacked in CFM, while in V Flow it not only shows flow direction intuitively, but also the flow velocity change in Jugular vein and carotid.




iFusion with Respiration Compensation

Improve the accurcy of fusion imaging to a new level and improve the precision of interventional diagnoses  and treatments.

slidebg1


Application 1

iFusion during intervention procedure



Application 2

Comparison of before and after respiration compensation (the left is pre-compensation and the right is post-compensation)

Benefits

Establish the model of liver motion along respiration accurately, remedy the respiration-induced fusion errors effectively

Markedly improve the fusion accuracy of full respiration cycles

Provides remarkable clinical values with ease of use, supporting various ultrasonic modes at the same time and providing target markers and safe margin

More timely and effective postoperative evaluation of the treatments



RIMT

IMT is a worldwide-recognized, economic and repeatable medical method to detect CVDs. But traditional IMT detection have some limitations. RIMT is based on Radio Frequency data, and provide the user extreme accurate IMT measurement.

The difference between RIMT and Traditional IMT

  Rimt case

RIMT(1)~RIMT(6): The maximum value in every heart cycle

RIMT(M): mean value of RIMT(1)~RIMT(6)

SD: standard deviation

ROI W: The width of ROI

Benefits

RIMT is good complement to traditional IMT Compare with traditional IMT can be applied on CCA,ECA, ICA and Bulb, RIMT can only be applied on CCA. But RIMT has higher accuracy when be applied on CCA, and it can be use together with ECG to detect intima-medium thickness in real time.

RIMT has more potential application and value to be explored. Since RIMT can measure the intima-medium thickness of every frames in a complete heart cycle, in the future, we can use RIMT together with ECG to detect intima-medium thickness in the same time of every heart cycle.

Improve early diagnosis of CVDs

Improve the effectiveness of pharmacy treatment follow-up

Reduce dependence on operator and image quality

iLive with Hyaline

Comprehensive upgrading on iLive to significantly improve the detailed resolution as well as anatomical realism. Hyaline is a new rendering method that dynamically applies transparency to rendered structures for a more comprehensive view of anatomy, therefore better displaying internal anatomy from a solid surface.

Natural Touch Elastography

Natural Touch Elastography provides multiple relative strain and stiffness parameters of cervix, uterus and ovary lesion.

slidebg1


Natural Touch Elastography

Natural Touch Elastography provides multiple relative strain and stiffness parameters of cervix, uterus and ovary lesion. With excellent sensitivity and stability, it provides further diagnostic information for more challenging demands.



UWN+ Contrast Imaging

UWN+ (Ultra-Wideband Non-linear Plus) CEUS enablesthe Resona 7 to detect and utilize both 2nd harmonic and non-linear fundamental signals, generating significantly enhanced images, resulting in greater sensitivity and longer agent duration for better understanding the GYN diseases.

Hycosy (HysterosalpingoContrastSonography)

A simple and well-tolerated ultrasound procedure used to assess the patency of the fallopian tubes, as well as detect abnormalities of the uterus and endometrium.

CEUS

CEUS enables the Resona 7 to detect and utilize both 2nd harmonic and non-linear fundamental signals, generating significantly enhanced images, resulting in greater sensitivity of minor signals and longer agent duration with lower MI.



Application above

CEUS QA Of Spleen Mass



Application above

  CEUS of Liver Cancer